iBall Nirantar 10003E UPS

 

  • 10KVA Online UPS System
  • Trendy and elegant LCD design for real-time UPS system information
  • High frequency and Double conversion online technology
  • Advanced Power Factor Correction
  • Comprehensive Self-Protection Design
  • Generator compatible
  • True Online – Zero transfer time
  • Microprocessor Control Guarantees High Reliability
  • Wide Input Voltage Range
  • User Selectable Output Voltage
  • Cold Start Function
  • Sine wave pulse width modulation
  • USB and RS232 communication port for monitoring
Key Points LCD Display: – Trendy and Elegant LCD Design for real-time UPS system information like Input / Output voltage and current, Load and Battery information, Bypass enable / disable selection information.
Microprocessor Control – By means of innovative software and control programs, the complicated hardware circuitry is inlaid in the powerful microprocessor. Apart from reduced size, it also lowers the defective rate of UPS.
Communication Port – User can control and monitor UPS status easily by using USB and RS-232 communication port or SNMP card (optional).
Modular Design – Nirantar Online is the modular design UPS. There are many small modular boards on the Power Board. The modular design helps technicians to maintain and repair the UPS easily and the product performance will be more stable.
Power Management Software – To provide the battery control of the Nirantar Online UPS, Software CD is bundled to monitor and manage UPS working status easily and in real time.
Selectable Output Voltage – Nirantar Online UPS enables user to select corresponding output voltage to the local mains power without changing hardware. Users can select output voltage by just pushing a button.
Input Capacity – 10000 VA / 8000 W
Phase – 1 phase in / 1 phase out
Voltage Range – Low Line Loss : 110 VAC ± 3% at 50% Load
176 VAC ± 3% at 100% Load
Low Line Comeback : 120 VAC ± 3% at 50% Load
186 VAC ± 3% at 100% Load
High Line Loss : 300 VAC ± 3 %
High Line Comeback : 290 VAC ± 3 %
Frequency Range – 46Hz ~ 54 Hz or 56Hz ~ 64 Hz
Power Factor – ≥ 0.99  @ 100% load
Output Frequency Range (Synchronized Range) –
46Hz ~ 54 Hz @ 50Hz system
56Hz ~ 64 Hz @ 60Hz system
Frequency Range (Batt. Mode) – 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio – 3:1 max
Harmonic Distortion – ≤ 3 % @ 100% Linear Load; ≤ 6 % @ 100% Non-linear Load
Output Voltage – 208/220/230/240VAC
Transfer Time – Bypass to Inverter (Line mode) : 0 ms
Inverter to Bypass (Line mode) : 0 ms
Waveform (Batt. Mode) : Pure Sinewave
Efficiency To AC Mode – 90%
To Battery Mode – 88%
Battery Numbers – 20
Charging Current (max.) – Default:4.0 A ±  10%,  Max.:6.0A ±  10%
Charging Voltage – 273 VDC ±  1% (based on 20 pcs batteries)
Battery Type – Depending on applications
Physical Dimension (D x W x H) – 442 x 190 x 318
Net Weight – 23
Enviroment Noise Level – Less than 58dBA @ 1 Meter
Management Smart RS-232 – Supports Windows? 2000/2003/XP/Vista/2008, Windows? 7, Linux, Unix, and MAC
Optional USB – Supports Windows? 2000/2003/XP/Vista/2008, Windows? 7, Linux, Unix, and MAC
Optional SNMP – Power management from SNMP manager and web browser
Operating Environment 0-95 % RH @ 0- 40°C (non-condensing)

 

Disclaimer:  Information is obtained from various sources and we can not guarantee that the information on this page is 100% correct.

Advertisements